What is the specifications and standards of scaffolding mats

As we all know, scaffolding is widely used in the construction of the project, but not just can be installed and used, there are certain norms and standards, then scaffolding pads specifications and stanards are what? here to see it.

Specifications and standards for scaffolding pads.

The pads should be made of wood, specifications for the long side to be more than 2 across, with a thickness of more than 50 millimeters, the width of the words to be more than 200 millimeters its role is to increase the area of steel pipe contact with the ground, so as to prevent the steel tube because of the small area of the force and settlement. now for the installation of external scaffolding requires elements of alkaline hardening treatment, there is no need to lay scaffolding boards.



The basic requirements of scaffolding erection,

1, Both the base and the mat must be accurately placed on the positioning line.

2, Single-row scaffolding horizontal bar can not be set up in the following positions: over the beam or with the ends of the 60-degree triangle within the range; width does not reach 1 meter between the window wall or freestanding columns, etc.; lightweight wall; mortar strength grade does not reach m2.5 brick wall, etc.

3, The construction load of each working layer should meet the relevant work requirements and should not be overloaded. Can not put the template bracket, transportation tube, etc fixed on the scaffolding, not allowed to hang lifting equipment.

4, The erection should be coordinated with the construction progress, the height of each erection can not exceed the adjoining wall of more than two steps

5, The main section must have a horizontal crossbar, with corner fasteners fastening forbidden to remove. double-row frame, if the wall from the end of the extension should be within 0.4 times the length of the center of the two nodes.

6, The length of the longitudinal horizontal bar should be greater than 3 spans, and is located in the inner side of the pole; need to use butt fasteners or lap if you need to join the long, butt butt fasteners should be staggered, two adjacent joints can not be located in the same span; different spans are staggered horizontally and the distance can not be less than 500 millimeters.

Conclusion: the above is about the specifications and standards for scaffolding pads are what and scaffolding erection of the basic requirements of the relevant content of the introduction, i hope this will be of some help to you.
Post time: 2024-10-10 14:33:33